![]() Here are the good news and bad news results: I then set up a circuit with speeds for both pumps as rstrouse described. I then did a factory reset of the IntelliCenter so that I was starting from scratch, and ran the setup wizard in the IntelliCenter and entered the info for my two VSF pumps (in the same way described in my original post). I could not change the internal address of the filter pump since the display is dead, but I am assuming it is set to address #1 by default (which I believe is what I want it set at anyway since I changed the address of the feature pump to address #2). Using the feature pump's display/keypad, I changed the internal address of the feature pump from address #1 (which is what it was in fact set at) to address #2. So with the above in mind, here is what I did based on Jimrahbe's post. I THINK this issue with the filter pump display not working is a completely separate and unrelated issue from me not being able to get the IntelliCenter to control the pumps, so I am going to ignore the issue of the display not working for the time being. The display of the filter pump does not show anything at all, does not light up, and looks dead (although I know the pump is receiving power as I can now get the pump itself to turn on - discussed below). The display of the filter pump is a different issue. the RPM's that the pump is currently running at, etc.). When in Auto mode, the display of my feature pump does NOT say "Display not Active." Instead, the display of the feature pump just shows the current pump control status and functions (i.e. Instead, the additional points raised by Jimrahbe are closer to what's causing my problems. What am I missing? When configuring the IntelliCenter do I need to do more than just using the Wizard which apparently just tells the IntelliCenter "hey there are two VSF pumps hooked up to you some where in some way." For example, is there something I need to do to get the IntelliCenter to sense, recognize, and communicate with the pumps that are hooked up to it? Do I need to do more than say "hey IntelliCenter there is a pump hooked up to you," and instead say something like "there is a pump hooked up to you AND it's hooked up to the relay labeled AUX 2"? Is there something else I need to do to get the IntelliCenter to recognize and communicate with the pump so that I can control it?Ĭlick to expand.After reviewing the posts by Jimrahbe and rstrouse and doing some further investigation on my equipment, I have determined that my problem is not simply that I needed to set up a circuit and speed for the Pool circuit on the pump. It however doesn't give me any options to change the pump speed, to turn on the pump, or control the pump in any way. In any event, when I click on either "VSF" or "VSF #2" it just takes me to a screen that shows Pump speed: 0 Flow rate: 0 and power usage: 0. Also, when I use the app and choose "Pumps" from the home screen, it takes me to a screen that shows two selectable options labeled "VSF" and "VSF #2" but there are red boxes next to each of them. For example, when I hit the "Pool" button, the pump doesn't turn on. After that though, I am not able to control the pump at all from either the screen on the IntelliCenter panel, or from the IntelliCenter iPhone app. I then repeat the process for the second pump, and finish the setup wizard and return to the home screen. ![]() When I run the setup wizard in the Intellicenter and get to the pump section, it asks me if I want to set up a pump and I say "yes." I then confirm all of the options for the pump (minimum speed, max speed, etc.) and hit next. The electrician has installed and connected everything to the IntelliCenter, and now I am trying to setup/configure the IntelliCenter to control everything. I also have two Pentair VSF 011056 pumps (one is the filter pump for the pool and spa, and the other is for the features). To give a little more info, I have an IntelliCenter i10PS. In short, I have an IntelliCenter and have completed the setup wizard, but I am not able to control either of my two pumps in any way with the IntelliCenter.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |